Sherman Oaks, Los Angeles, California: Wildfire-Zone Windows and Doors
Wildfire resistant windows and thermal break sliding doors for Southern California:
solar heat gain, wide temperature swing and wildfire-zone glazing.
Los Angeles, California
fixed lights and a hinged
entrance door
TY150 thermal break sliding
PRO110 casement and fixed
throughout
Local Climate
Southern California, San Fernando Valley. Hot dry summers with strong year-round sun, mild wet winters, and a wide day-to-night temperature swing. Hillside sites fall within the state’s wildfire hazard zones, so the glazing has to meet wildfire-zone requirements. No hurricanes.
Key Challenges
Solar heat gain through large west and south-facing glazing. California Energy Code limits on U-factor and SHGC. Tempered glazing required in wildfire hazard zones for every exterior opening. Long sliding spans that still have to run smoothly and seal.
EMD Solution
Low-E thermal break aluminum to hold down solar heat gain. Tempered insulated glazing units throughout, as required for wildfire-zone openings. Multi-panel sliding systems set out for the openings on this house.
Final Result
Multi-panel sliding doors, corner glazing, full-height fixed lights and a hinged entrance door,
installed across the house and the pool terrace.
Product Specifications
TY120 Thermal Break
Sliding Doors
| Profile Wall Thickness | 2.0mm |
|---|---|
| Frame Width | 120mm |
| Opening Options | Push-And-Pull |
| Glass Configuration | 5mm+20A+5mm Tempered Insulated Glass |
| Hardware System | EMD System |
Typical Performance
| Wind load resistance | 1,600 Pa, EN 12210 Class C4 |
|---|---|
| Water tightness | Class 6A, 250 Pa, EN 12208 |
| Air permeability | Class 3, EN 12207 |
| Max sash size | 1,500 × 2,700 mm, up to 150 kg per panel |
| Finish | Powder coating to AAMA 2603 PVDF to AAMA 2605 for coastal exposure |
TY150 Thermal Break
Sliding Doors
| Profile Wall Thickness | 2.0mm |
|---|---|
| Frame Width | 150mm |
| Opening Options | Push-And-Pull |
| Glass Configuration | 5mm+27A+5mm Tempered Insulated Glass |
| Hardware System | EMD System |
Typical Performance
| Wind load resistance | 1,800 Pa, EN 12210 Class C4 |
|---|---|
| Water tightness | Class 7A, 300 Pa, EN 12208 |
| Air permeability | Class 3, EN 12207 |
| Max sash size | 1,800 × 2,800 mm, up to 200 kg per panel |
| Finish | Powder coating to AAMA 2603 |
Specifying for a California project?
Send us your opening schedule or drawings. We return a California project window quote within 24 hours, with NFRC data for the configurations you need.
Drawings
Window shop drawings for every opening, set out on a numbered opening schedule that matches the architect’s plans. Drawings cover elevations, sections and installation details. Production starts only after the client signs off on the drawings.
Production & QC
Window quality control inspection runs at four points on every unit before packing, and the photos are sent to the client during production.
Packing & Shipping
Every unit is crated for export on timber pallets with edge protection and film wrap, then loaded into containers at the factory.
Installation
EMD technicians attended site to provide window installation supervision, working alongside the client’s local crew.
EMD uses the information you provide to respond to your enquiry about our products and services. You can unsubscribe at any time. For more, see our Privacy Policy.
We reply within 24 hours · WhatsApp 7 days a week · No commitment required